Boiler fault codes explained

Read time. Icon
8 min read

Dive into Padly's thorough guide on boiler fault codes. Learn about common codes, their meanings, and how professional boiler engineers resolve these issues to restore optimal boiler performance.

Boiler showing a fault code and no heating or hot water? Book a boiler repair online and a Gas Safe registered engineer can diagnose it. This page helps you read the code first and shows what the makers say you can safely check yourself.

A fault code is your boiler telling you which part of its self-test failed. It points at a system, such as water pressure, ignition or a temperature sensor. It rarely names the broken part. The same code can also mean different things on different boilers, so the maker's manual is always the final word. This guide covers what to check first and what the codes on Ideal, Vaillant and Baxi boilers mean according to those makers.

At a glance

  • Codes aren't universal. F1 means low pressure on an Ideal boiler, and Vaillant's low-pressure code is F.22.
  • Safe checks: water pressure, radiator valves, gas supply and prepayment credit, a frozen condensate pipe in cold weather and one reset.
  • Don't take the casing off. Vaillant says opening the boiler can be dangerous, and gas work is for a Gas Safe registered engineer.
  • Sensor, fan and flame faults, and anything repeated, need an engineer.
  • If you smell gas or a carbon monoxide alarm sounds, call 0800 111 999.

What to check before you read the code

Several fault codes come from the same few causes, and some are quick to rule out. These are the checks the makers themselves suggest.

Water pressure

Low pressure is behind a lot of codes. Ideal says the pressure should be 1 to 1.5 bar, and it lists a low pressure fault among its codes. Vaillant gives the same range. Our simple guide to boiler pressure explains how to read the gauge and top up a combi, and the boiler pressure guide compares the makers' figures.

Radiator valves and airlocks

Ideal's advice for a flow overheat or no-flow code starts with making sure the radiator valves are open. Vaillant also says to check for airlocks and that radiator valves, external pumps and zone valves are working.

Gas supply

If the boiler can't light, check whether other gas appliances, such as a hob, are working. If you have a prepayment gas meter, check there's credit. Ideal and Vaillant both list these checks. Ideal also says to check that the yellow gas isolation valve under the boiler hasn't been turned off, and that when it's on, the handle points along the pipe.

A frozen condensate pipe

In cold weather, a frozen outdoor condensate pipe can stop a boiler firing. Vaillant lists ice in the condensate pipe among the checks for its ignition codes. Our frozen condensate pipe guide shows how to deal with it.

One reset, then stop

Vaillant says resetting a boiler can often clear a fault or get it working for a while. Ideal's guidance for several codes starts with a reset too. Do it once, using your user manual. Ideal says if the boiler has been reset too many times in 15 minutes, turn the power off and on again to reset it. A fault that keeps coming back needs an engineer, not a fifth reset.

Fault codes by maker

Find your boiler's make and model on the front or in the manual, then use the matching list. These tables summarise what each maker publishes. They aren't a full list, and your own manual covers every code for your model.

Ideal Heating

Ideal boilers flash a letter and a number, such as L and 2. Ideal publishes these homeowner actions:

CodeWhat Ideal says it meansWhat Ideal says to try
F1Low pressureTop up to between 1 and 1.5 bar.
F2 or L2Flame loss or ignition lockoutReset. Check prepayment credit, other gas appliances and the yellow isolation valve. A gurgling noise while firing means a call to your installer.
L1Flow temperature overheat or no water flowOpen all radiator valves, check the pressure is 1 to 1.5 bar and reset.
L3No water flowCheck the pressure, check the isolation valve, bleed radiators, check the pressure again and press reset.
L5Reset too many times in 15 minutesTurn the power off and on to reset.
L6False flame lockoutReset. If it persists, an engineer visit is needed.
F3Fan faultReset, then call if it persists. It needs an engineer.
F4, F5, F6, F0Flow thermistor, return thermistor, outside sensor, no-water-flow thermistorReset, then call if it persists. They need an engineer.
F7Low mains voltageThe voltage to the boiler may be too low. Ask an electrician to inspect the electrics.

Ideal tells you to quote the code when you call it. The page mentions a gurgling noise during firing because that can point to a blockage, which is an installer's job.

Vaillant

Vaillant codes start with F and a full stop, such as F.22. Vaillant says each is either something you may be able to check or a job for an engineer, and that opening the boiler casing can be dangerous.

CodeWhat Vaillant says it meansWhat Vaillant says to do
F.0, F.1Flow or return temperature sensor interruptedA job for a Vaillant engineer. Possible causes are the sensor's electrical connection or a defective sensor.
F.20Safety thermal cut-out has operatedCheck the pressure and refill if needed, look for leaks, check radiator valves are open and that there are no airlocks. Vaillant says to contact your installer in the first instance.
F.22Low water pressureIf it's below 1 bar, you can top up to 1 to 1.5 bar if you're competent to do so, at your own risk. Otherwise ask an engineer.
F.27Flame signal while the burner is offA case for an expert. Possible causes are a gas solenoid valve that isn't leaktight or a faulty circuit board.
F.28No flame signal at ignitionCheck other gas appliances, prepayment credit and any ice in an outdoor condensate pipe. Otherwise it needs an engineer.
F.29Ignition after a flame loss was unsuccessfulThe same checks as F.28. Causes include an interrupted gas supply, a flue gas blockage or recirculation and a blocked condensate pipe.
F.32Fan faultA case for a Vaillant engineer.

Vaillant says it will attend to any fault code but reserves the right to charge a call-out fee for non-product faults. That's another reason to run through the simple checks first.

Baxi

Baxi's digital-gauge guidance says that a Baxi boiler showing A.02.06 or H.02.07 has pressure that's too low to work, and it needs topping up. Baxi's professional error-codes page explains the most common codes, but says installer actions for fixing them sit behind a Baxi Works login. So for a Baxi boiler, check the pressure first, then use your manual or call an engineer.

Worcester Bosch, Glow-worm, Viessmann and others

Use your user guide or the maker's own fault code page. Viessmann runs a fault code checker on its UK site. The codes differ even within one brand, because they depend on the model and the control board.

What the codes have in common

Whatever the maker, most codes fall into five groups:

  • Pressure and water flow. Low pressure, no flow, or an overheat that comes from poor circulation.
  • Ignition and flame. The boiler can't light, loses its flame, or detects a flame it shouldn't. That points at the gas supply, a blocked condensate pipe, the electrodes or the flue.
  • Temperature sensors. Flow, return and outside sensors that have disconnected, short-circuited or failed.
  • Fans and flue. A fan that won't run, or a blocked flue gas route.
  • Power and controls. Low mains voltage, or a circuit board fault.

The first group is the one you can often influence. The rest usually need an engineer, and the second and fifth involve gas and electrics.

When to stop and call an engineer

The Health and Safety Executive (HSE) says anyone employed to work on gas appliances in a home must be Gas Safe registered and competent for that work, and it's illegal to use a gas appliance you suspect is unsafe. Turn it off and don't touch it until a Gas Safe registered engineer has checked it. Call an engineer if:

  • the code keeps coming back after one reset;
  • it's a sensor, fan, flame or circuit board code;
  • the boiler is leaking, making new noises or smells odd;
  • pressure keeps falling, which usually points to a leak somewhere in the system;
  • you're not sure what the code means for your model.

It helps to have the make, model and exact code to hand, along with anything you've already tried. Book a boiler repair and give those details. If the boiler is old and the repairs keep coming, you can get a boiler quote online to compare. A yearly boiler service is the best way to catch many of these faults before they stop the heating.

Gas smells and carbon monoxide

If you smell gas and the smell is strong, or you feel unwell, don't stop to do anything else. Get outside into the fresh air and call the National Gas Emergency Service on 0800 111 999 from there. The call is free and the line is open 24 hours a day. For a fainter smell, National Gas advises that you don't smoke or light matches, don't switch anything electrical on or off and open doors and windows. Turn the gas off at the meter control handle only if you can reach it safely, and not if the meter is in a cellar. Then call 0800 111 999.

If a carbon monoxide alarm sounds or you suspect a leak, National Gas says to stop using all appliances, open doors and windows, evacuate the property immediately and call 0800 111 999. Don't go back in until you've had advice. Symptoms include headaches, dizziness, nausea and breathlessness, and the Health and Safety Executive says to seek urgent medical advice if you or your family have them. The NHS says to call 999 or go to A&E if someone has been exposed and finds it hard to breathe.

Quick answers

What does a boiler fault code mean?

It's a short code the boiler shows when its self-checks find a problem, such as low pressure, an ignition failure or a sensor fault. The meaning depends on the make and model, so check your manual or the maker's list.

Do fault codes mean the same thing on every boiler?

No. On an Ideal boiler F1 means low pressure, while Vaillant's low-pressure code is F.22. Always use the list for your make and model.

Can I reset my boiler?

Yes, once. Vaillant says resetting often clears a fault or gets the boiler working for a while, and your manual shows how. If the code returns, or Ideal's L5 appears after repeated resets, stop and call an engineer.

What is the most common boiler fault code?

Low pressure is the one the makers keep coming back to. Vaillant calls it a common issue, and each brand has a code for it: F1 on Ideal, F.22 on Vaillant and A.02.06 or H.02.07 on Baxi. It can often be fixed by topping up to 1 to 1.5 bar, if you can identify the filling controls.

What should the pressure be?

Ideal and Vaillant both give 1 to 1.5 bar. Check your own manual, because figures vary by boiler.

Can I fix an ignition fault myself?

Only the simple checks: other gas appliances, prepayment credit, the isolation valve and ice in the condensate pipe. After that it's a job for a Gas Safe registered engineer.

Is a fault code dangerous?

Not by itself, but don't ignore it. If you smell gas or a carbon monoxide alarm sounds, leave the property and call 0800 111 999. If you suspect the boiler is unsafe, turn it off and don't use it until it's been checked.

Do I have to pay a call-out fee?

That depends on who attends and the cause. Vaillant, for example, says it may charge a call-out fee for non-product faults.

Sources, checked 28 November 2026

Last updated 28 November 2026. Boiler still showing a code? Book a boiler repair.