A frozen condensate pipe can stop your boiler working during a cold spell. You may hear gurgling and lose heating or hot water. If you can safely reach the frozen section from ground level, you can usually thaw it with warm water. Leave awkward access or a boiler that still won't work to an engineer.

If your boiler still won't fire up, book a boiler repair online with Padly's Gas Safe registered, insured engineers.

At a glance
  • The condensate pipe carries waste water away from a condensing boiler, usually through plastic pipework.
  • A frozen outside section can cause gurgling and stop the boiler working.
  • Use warm water or a hot water bottle, and only work where you can reach from ground level.
  • Water falling onto paths may freeze and become slippery.

If you smell gas or suspect a gas leak, don't use switches or boiler controls; follow the emergency steps on this page.

What the condensate pipe does

A condensing boiler produces waste water during normal operation. The condensate pipe takes that water to household drainage or an outside soakaway. It is normally plastic, often white or grey, and may look rather like the waste pipe from a sink.

You may see it coming through the outside wall and heading down towards a drain. Some condensate pipes connect straight into another waste pipe, such as the sink's, so there isn't always an obvious outside run.

Prolonged freezing weather can block an exposed section with ice. Baxi points out that outside pipework is more prone to freezing than pipework inside the building.

Signs to look for on the boiler

Listen for gurgling or bubbling near the boiler or condensate pipe. If the boiler has stopped supplying heating or hot water during freezing weather, an icy blockage is one possible explanation. Check the display against your boiler manual before trying to thaw anything.

Baxi explains that shutdown protects the boiler from water backing up into it and damaging components, including the electrics.

The codes below are the ones these manufacturers mention for frozen condensate. Check the code for your own make of boiler.

MakerWhat you may seeMaker's advice
Worcester BoschGurgling; possible EAWarm water; reset after thawing
VaillantF28 or F29Thaw; check manual before reset
BaxiMost models: E133 or E28Clear blockage; follow restart guide

On a Baxi, the display may alternate between E1 and 33. Baxi also lists gas-supply or ignition problems as possible causes of E133, so that code alone doesn't prove the condensate pipe is frozen.

Find the frozen section outside

Start by tracing the plastic pipe from the bottom of the boiler towards the outside wall and drain. Baxi suggests looking for a slight downward slope towards the drain. You only need to inspect what you can safely reach.

The blockage is likely to be at the most exposed point. That could be the open end, an elbow or a dip where water collects. Identify the affected section as closely as you can before applying warmth.

Leave a high pipe alone rather than climbing up for a closer look.

How to thaw a frozen condensate pipe

HHIC's industry guidance prefers an installer or service engineer to do this work, but gives householders thawing options if they feel competent. Only attempt these steps if you've identified a frozen section and can reach it easily from ground level.

Worcester Bosch, Vaillant, Ideal and Baxi all warn against boiling water. Warm or tepid water is enough for the methods below.

  1. Check your footing and access. Don't use a ladder to reach the condensate pipe. Watch where poured water will land, particularly if the pipe is above a path or walkway: that water can freeze and create a slipping hazard.
  2. Ideal says to remove any fitted insulation before thawing and refit the sleeves afterwards. Keep the sleeves to hand while you work.
  3. Apply gentle warmth close to the blockage. Hold a hot water bottle or microwaveable heat pack against the outside of the pipe. A cloth soaked in warm water is another option.
  4. Alternatively, pour warm water along the affected section from a watering can or similar container. Keep an eye on the ground as you pour. Vaillant advises continuing until the ice comes out or the pipe drains.
  5. Baxi warns against direct heat sources, and Citizens Advice says not to put too much weight on the pipe. Use gentle warmth without loading the pipework.
  6. Once the blockage has cleared, follow your boiler's operating instructions to clear the fault and restart. If the boiler still doesn't work, stop and arrange an engineer's visit.

Reset using the controls for your model

Wait until the condensate blockage has cleared before restarting. Check the operating instructions or the manufacturer's website for your boiler's reset method. A button sequence from another boiler isn't a substitute for your own instructions.

On a Baxi with a dedicated reset button, press reset until the red lockout light goes out.

For Baxi's thermostat-knob arrangement, turn the temperature control fully anticlockwise, hold it there until the red lockout light goes out, then turn it back to the setting you want. On Baxi's selector-switch arrangement, turn to R, hold for at least five seconds and release.

Use only the method that matches your boiler. Baxi says frequent lockouts indicate a fault that needs your installer or service engineer.

Help prevent the condensate pipe freezing again

Insulation reduces the risk of another freeze. Ideal recommends waterproof foam insulation for the outside run. Its service advice includes checking the pipe's fall, route and insulation; for new installations, it describes a larger external pipe diameter as industry best practice against blockage.

Ask about the condensate pipe when arranging your boiler's annual service.

Worcester Bosch's cold-weather advice includes turning the heating control on the boiler to maximum, insulating external pipework and fitting a drain cover to protect the end.

After the pipe has successfully thawed and the boiler has restarted, HHIC suggests temporarily setting the boiler thermostat to maximum if severe weather continues. This is the control on the boiler, rather than the room thermostat.

Under the same conditions, HHIC also suggests temporarily using continuous heating, with the room thermostat around 15°C overnight. Return the controls to their usual settings once the cold spell ends.

When to stop and book an engineer

Leave a high or awkwardly placed condensate pipe to an engineer. If thawing and following the restart instructions haven't restored operation, arrange a Gas Safe registered engineer to look at the boiler. For a different fault code, use the manufacturer's guide rather than carrying on with frozen-pipe checks.

Vaillant advises contacting a Gas Safe registered engineer if the condensate pipe keeps freezing despite precautions. You don't have to keep repeating the same thawing routine.

Keep the boiler casing closed and leave internal repairs and gas components to an engineer. HSE says anyone employed for domestic gas-appliance work must be Gas Safe registered and competent for that work. The back of their Gas Safe ID card lists their competencies.

In England, Citizens Advice says to tell your landlord if the boiler isn't working. Repair or replacement is the landlord's responsibility. Don't try to fix the boiler yourself if you're a tenant.

If you smell gas or suspect a gas leak: National Gas says not to smoke or light matches. Don't turn electrical switches on or off, including the boiler's controls and switches. Open doors and windows. Turn off the gas at the meter control handle unless the meter is in the cellar. Go outside and call the National Gas Emergency Service on 0800 111 999.

If a carbon monoxide alarm sounds or you suspect carbon monoxide: Stop using all appliances; switch them off only if there's no smell or suspicion of a gas leak. Open doors and windows to ventilate, then leave immediately. Call 0800 111 999 from outside, seek immediate medical help and wait for emergency advice before returning, as National Gas advises. HSE confirms that carbon monoxide has no smell. Fresh air alone won't treat exposure.

Orange pilot flame, or another worry that the boiler is unsafe, with no smell or suspicion of gas: don't relight it. Turn the boiler off and leave it untouched until a Gas Safe registered engineer has checked it, as Citizens Advice and HSE advise. For an orange pilot flame, Citizens Advice also says to go outside and call 0800 111 999.

Padly's engineers are Gas Safe registered and insured. Padly checks this, and holds its own insurance up to £10m. Book a boiler repair using the online form.

Checked on 27 November 2026. Sources: Worcester Bosch frozen condensate advice | Vaillant winter pipe guidance | Ideal thawing guidance | Baxi thawing guide | Baxi freezing FAQ | HHIC householder guidance | Baxi reset controls | Citizens Advice boiler checks | HSE domestic gas FAQs | National Gas emergency advice.

Related Padly guides

Frequently asked questions

Can I use boiling water on the condensate pipe?

No. Use warm or tepid water on the frozen condensate pipe. Boiling water can damage the pipe. Pour from a watering can or similar container, and watch for water freezing on the path beneath you.

Which codes can appear with a frozen condensate pipe?

For a frozen condensate pipe, Worcester Bosch mentions a possible EA code, Vaillant lists F28 or F29, and Baxi gives E133 or E28 on most models. Baxi also lists gas-supply or ignition problems for E133, so the code alone doesn't confirm a frozen condensate pipe.

What should I do if the condensate pipe keeps freezing?

Arrange an engineer's inspection if the condensate pipe keeps freezing despite precautions, as Vaillant recommends. Insulation can reduce freezing risk. Ideal's service guidance includes checking the pipe's fall, route and insulation, so ask about those when arranging the boiler's service.

What if I think the boiler is unsafe?

If you smell gas or suspect a gas leak, don't use switches or boiler controls. Open doors and windows, turn the gas off at the meter unless it's in the cellar, go outside and call 0800 111 999. For a carbon monoxide alarm or suspected carbon monoxide, leave immediately, call that number from outside and seek immediate medical help.

When should I restart the boiler after thawing?

Clear the frozen condensate pipe blockage before restarting the boiler. Use your boiler's operating instructions or the manufacturer's website for the reset method. If the boiler still won't work after that, stop and arrange a Gas Safe registered engineer.

Who arranges the boiler repair if I rent?

Tell your landlord the boiler isn't working. Citizens Advice's guidance for England says the landlord is responsible for repair or replacement and tenants shouldn't try to fix the boiler themselves.

Can I reach a frozen condensate pipe using a ladder?

Leave the frozen condensate pipe to an engineer if you can't reach it easily from ground level. Don't climb a ladder to thaw it. Ask for help if access is awkward or you're unsure about doing the task.

Will thawing the condensate pipe get the boiler working?

Once the frozen condensate pipe is clear, follow your boiler's own restart instructions. If the boiler still won't work, arrange a Gas Safe registered engineer to inspect it rather than repeating the reset.