Boiler no hot water? Checks for combi boilers and when to call an engineer

No hot water can mean a supply problem, changed controls or a boiler fault. If you smell gas or suspect a gas leak, don't use switches or boiler controls; follow the emergency steps on this page. For a combi, Baxi says heating without hot water may point to a stuck diverter valve, which needs an engineer.

If your taps still stay cold, book a boiler repair online with Padly's Gas Safe registered, insured engineers.

At a glance
  • No separate hot-water cylinder usually means you have a combi.
  • Read the display code and check its meaning in your boiler manual.
  • For combis, Baxi and Viessmann identify a stuck diverter as a possible cause of heating without hot water. Repairs need an engineer.
  • Use your own boiler's pressure instructions, rather than copying another model's setting.
  • In England, tell your landlord if your rented home's boiler stops working.

Before you touch the boiler

Work out which hot-water system you have

Look for a separate hot-water cylinder, perhaps in the airing cupboard. Without one, you usually have a combi. A combi heats tap water on demand, as Vaillant explains, rather than waiting for a stored cylinder to heat up.

With a cylinder, check the hot-water programme as well as the boiler. If you've used up the stored hot water, the cylinder needs time to heat again. Keep these two arrangements in mind as you work through the checks, so you're looking at the right controls.

Read the display and check the supplies

Start with what you can see on the boiler front. Write down the full fault code or warning light and look it up in the user manual. Keep that note for the engineer if you need one. Follow any instruction in the manual to call an engineer.

A blank display can mean there's no power, Viessmann explains, so check whether your lights work. Citizens Advice recommends checking prepayment electricity credit and the boiler and wall switches. If a circuit breaker trips again after being reset, stop and ask a registered electrician to investigate.

Try a cold tap. Ideal explains that a water-supply interruption can leave the heating working but the hot water off: a combi is affected straight away, while a stored-water system is affected when its tank empties. No cold water points towards the supply, which could have been shut off or frozen.

Only with no gas smell, suspected gas leak, orange flame or other emergency warning, Ideal suggests trying a gas hob for a few seconds. A flame that dies down can indicate the gas supply is off. Check a prepayment gas meter has credit. Contact your gas supplier if you suspect a wider supply problem; don't start work on the boiler's gas valve.

Check the hot-water controls and pressure

Check hot water hasn't been set to off at the boiler or programmer. A dial may have been turned or a switch flicked without you noticing, as Baxi points out. Check your normal setting before changing anything else.

For timed hot water, compare the clock and programme with when you actually need it. Vaillant says a power cut or the clocks changing can upset the timer. That advice doesn't apply to combi tap water, which heats on demand.

Read the pressure gauge. Baxi says the right pressure depends on your boiler, so check your own manual before opening a filling valve.

Before topping up, find the filling controls your manual describes. If you're unsure which valve to use, Baxi advises asking an engineer. Citizens Advice says the heating should be off and the boiler cool, with the filling valves closed properly afterwards. Baxi warns against adjusting pressure cut-off safety controls.

See our guides to checking boiler pressure and using heating and hot-water controls for more detail.

Combi boiler no hot water

Hot radiators and cold taps are useful details to tell an engineer. After the supply, pressure and control checks, Baxi, Vaillant and Viessmann identify a stuck diverter valve as a possible cause in a combi. This valve directs heat towards the radiators or the taps and showers.

Leave a suspected diverter fault to an engineer. Use a Gas Safe registered engineer for this repair.

To describe how the heating responds, follow Viessmann's check:

  1. Check the room thermostat hasn't been set to off.
  2. Raise its temperature setting with the timer set to active.
  3. See whether the boiler fires, and note the result.

If it doesn't respond, Viessmann says the thermostat may need attention from a trained engineer.

If you have a hot-water cylinder

Check the hot-water programme runs at the right times and look at the cylinder thermostat. Citizens Advice gives at least 60°C for this thermostat. If you've used up the stored hot water, allow the cylinder to heat again before expecting more at the taps.

An immersion heater, where fitted, can provide extra hot water. Keep to its normal user controls.

Checks for your boiler brand

Worcester Bosch

For the Greenstar i, Worcester Bosch gives around 1 bar with the heating off, usually rising to 1.5 bar or more during operation. Below 1 bar needs topping up under that guidance. Match the instructions to the internal filling-key or keyless arrangement fitted to your boiler.

The Greenstar i's ‘quick info’ button shows descriptions of its current status. If no lights stay lit, check the power supply carefully or ask for help. If power is present but the lights remain off, you need an engineer. Get advice about repeated pressure loss too.

Vaillant

Deal with the cause before resetting, such as low pressure or a frozen condensate pipe, following Vaillant's guidance. Use only the adjustments your user manual allows. The reset controls vary by model.

If an older boiler's pilot light is out, Vaillant says to follow the manual's user instructions. Don't remove the casing. If you smell gas or suspect a gas leak, or the flame is orange, don't relight it: use the emergency steps below. If the pilot still won't light, contact a Gas Safe registered engineer.

Ideal

On Ideal boilers, pressure below 1 bar will probably make the boiler shut down automatically. Ideal's F1 advice identifies low pressure and gives 1 to 1.5 bar for topping up. Follow your model's filling instructions. Repeated pressure loss needs a Gas Safe engineer.

Ideal lists L2 as flame loss or ignition lockout. With gurgling while the boiler tries to fire, contact the installer because there may be a blockage. L5 means the boiler has been reset too many times in 15 minutes. Stop trying further resets and report the fault.

Baxi

Baxi suggests around 1 bar, but says to check the correct pressure in your own boiler manual. Ask an engineer if you can't identify the filling controls. If the earlier hot-water checks haven't helped, arrange an engineer's visit.

For a reset, Baxi describes different controls. Match yours to the manual:

  • Dedicated reset button: press until the red lockout light goes out.
  • Thermostat knob: turn fully anticlockwise, hold until the light goes out, then restore the desired setting.
  • Selector switch: hold at R for at least five seconds, then release.

In freezing weather, check the condensate pipe

The condensate pipe carries waste water away from a condensing boiler, as Worcester Bosch explains. It's normally plastic and runs towards drainage. Vaillant identifies an outside section freezing as a possible cause of lost heating and hot water, and gurgling can be a clue.

Only tackle an identified frozen section you can safely reach from the ground. Ideal advises tepid water; Worcester Bosch, Vaillant, Ideal and Baxi all warn against boiling water. Don't use a ladder. Watch for water freezing on paths and making them slippery.

Once the blockage clears, Baxi advises checking your boiler's restart instructions and calling a Gas Safe engineer if it still won't work. Our frozen condensate pipe guide explains the full sequence.

When to stop and book an engineer

If the boiler won't restart or the same fault returns, Viessmann advises contacting a heating engineer. Stop repeating the checks.

Leave the casing, gas valve and internal repairs alone. HSE requires anyone employed to work on domestic gas appliances to be Gas Safe registered and competent for that work. If you smell gas or suspect a gas leak, don't use switches or boiler controls; the emergency steps are just below.

In England, Citizens Advice says to report a broken boiler to your landlord, who is responsible for repair or replacement. Don't attempt the repair yourself. If you own the home, check existing warranty, guarantee and insurance documents before arranging paid work. Compare parts and labour cover, and ask the manufacturer if the paperwork is missing.

If you smell gas or suspect a gas leak: National Gas says not to smoke or light matches. Don't turn electrical switches on or off, including the boiler's controls and switches. Open doors and windows. Turn off the gas at the meter control handle unless the meter is in the cellar. Go outside and call the National Gas Emergency Service on 0800 111 999.

If a carbon monoxide alarm sounds or you suspect carbon monoxide: Stop using all appliances; switch them off only if there's no smell or suspicion of a gas leak. Open doors and windows to ventilate, then leave immediately. Call 0800 111 999 from outside, seek immediate medical help and wait for emergency advice before returning, as National Gas advises. HSE confirms that carbon monoxide has no smell. Fresh air alone won't treat exposure.

Orange pilot flame, or another worry that the boiler is unsafe, with no smell or suspicion of gas: don't relight it. Turn the boiler off and leave it untouched until a Gas Safe registered engineer has checked it, as Citizens Advice and HSE advise. For an orange pilot flame, Citizens Advice also says to go outside and call 0800 111 999.

Padly's engineers are Gas Safe registered and insured. Padly checks this, and holds its own insurance up to £10m. Book a boiler repair using the online form.

Checked on 27 November 2026. Sources: Vaillant hot-water checks | Baxi hot-water checklist | Ideal boiler troubleshooting | Ideal fault codes | Worcester Bosch Greenstar i troubleshooting | Viessmann heating and hot-water checks | Baxi reset guide | Ideal frozen-pipe guidance | Vaillant frozen-pipe advice | Worcester Bosch condensate advice | Baxi condensate restart advice | Citizens Advice boiler guidance | HSE domestic gas FAQs | National Gas emergency contacts.

Related Padly guides

Frequently asked questions

Why do the radiators heat up while the taps stay cold?

In a combi boiler, a stuck diverter valve is one possible cause once supply, pressure and control checks have been ruled out, according to Baxi and Viessmann. A diverter repair needs an engineer. Ideal also notes that an interrupted water supply can affect hot water while the central heating continues.

What should I check on a combi with no hot water?

Read the boiler display, look up the code in your manual and check the supplies, hot-water controls and pressure against your model's instructions. If you smell gas or suspect a gas leak, don't use switches or boiler controls; follow the emergency steps on this page.

Can I repair the boiler's diverter valve myself?

Leave the boiler's diverter valve to an engineer. Vaillant advises against repairing it yourself, and Viessmann specifies a Gas Safe engineer. The valve may need cleaning or replacing.

When should I stop resetting the boiler?

If the boiler keeps shutting itself down, Baxi advises contacting the installer or service engineer. Follow the reset instructions in your boiler manual, and get a recurring fault investigated rather than pressing reset again and again.

What pressure should my boiler show?

Check your boiler manual. Worcester Bosch gives around 1 bar with heating off for the Greenstar i; Ideal's F1 advice gives 1 to 1.5 bar for topping up. Use the pressure in your own boiler's instructions; don't copy another boiler's setting.

Why can hot water stop in freezing weather?

The condensate pipe carries waste water from a condensing boiler, as Worcester Bosch explains. Vaillant says an outside section can freeze and stop heating and hot water. Ideal advises tepid water, never boiling, and only on a frozen section you can safely reach from the ground. Watch for water freezing on paths.

Who should arrange repairs in a rented home?

In England, tell your landlord the boiler isn't working. Citizens Advice says the landlord is responsible for repairing or replacing the boiler. Don't try to repair the boiler yourself.

Which boiler warnings need emergency help?

If you smell gas or suspect a gas leak, don't use switches or boiler controls. Open doors and windows, turn the gas off at the meter unless it's in the cellar, go outside and call 0800 111 999. For a carbon monoxide alarm or suspected carbon monoxide, leave immediately, call that number from outside and seek immediate medical help.

For help with taps that stay cold, Book a boiler repair online with Padly.