How to bleed a radiator, step by step

To bleed a radiator, turn the heating off and let it cool, open the little valve at the top corner with a radiator key until the hissing stops and water appears, then close it. Afterwards, check the boiler pressure. It's a five-minute job for each radiator.

If bleeding doesn't fix a cold radiator, or you're bleeding the same ones every few weeks, something else is going on. Book a boiler repair online and one of our Gas Safe registered, insured engineers can find out why.

At a glance

  • A radiator that's cold at the top and warm at the bottom usually has trapped air. That's what bleeding fixes.
  • Cold at the bottom and warm at the top is different. Worcester Bosch says that usually means sludge.
  • Worcester Bosch says to turn the heating off for around 30 minutes first, so the water isn't hot.
  • You need a radiator key (or a flat screwdriver for some valves), a cloth and something to catch drips.
  • Bleeding lets water out, so check the boiler pressure afterwards. Baxi gives about 1.5 bar.

Does your radiator need bleeding?

Put the heating on and give it time to warm up. Then go round and carefully feel each radiator, top and bottom. They can get hot enough to hurt, so use the back of your hand and keep it brief.

What you're feeling for:

  • Cold at the top, warm lower down. Air has collected at the top. Bleed it.
  • Warm at the top, cold at the bottom. Bleeding won't help. Worcester Bosch says this usually points to sludge or debris in the radiator. See our guide to radiators cold at the bottom.
  • Cold all over, while the others are hot. Check its valves are open first. It could also be air, a stuck valve or a balancing problem.
  • Gurgling or trickling sounds. Vaillant says gurgling is trapped air moving round with the water. Bleeding is the first thing to try.

Worcester Bosch says air can build up in radiators during normal running, and that left alone it can cause poor circulation, cold spots and even boiler faults. So it's worth doing when you notice it, not just at the start of winter.

What you'll need

  • A radiator key. They're cheap and sold in most DIY shops. Some newer bleed valves take a flat-head screwdriver instead.
  • An old towel or cloth to hold under the valve.
  • A small bowl or cup to catch water, especially on carpet.

Don't force a tool that doesn't fit the valve. If the key slips or the pin looks worn, stop there rather than risk damaging it.

How to bleed a radiator, step by step

This follows the steps Baxi, Worcester Bosch and Vaillant give. They're almost identical.

  1. Turn the heating off. Worcester Bosch says to leave it for around 30 minutes so the system cools. Hot water can scald, and with the pump stopped you're not pulling more air round while you work.
  2. Find the bleed valve. It's a small valve at one of the top corners of the radiator, usually with a square pin or a slot in the middle.
  3. Get ready for drips. Fold the cloth under the valve and hold the bowl beneath it.
  4. Open it slowly. Fit the key and turn it anticlockwise, slowly and only a little. Worcester Bosch says a slight turn is all it takes. Listen for the hiss of air escaping.
  5. Wait for water. When the hissing stops and water starts to come out in a steady dribble, the air has gone.
  6. Close it. Turn the key clockwise until it's shut. Worcester Bosch says to close it tightly by hand. Don't lean on it.
  7. Do the next one. Repeat on every radiator that was cold at the top.
  8. Check the pressure. See the next section.
  9. Turn the heating back on. Once it's warmed up, feel the radiators again. They should heat evenly from top to bottom.

If water spurts out hard or the valve won't close, close it as best you can and put a towel round it. Then get an engineer to look at it.

Check the boiler pressure afterwards

Every bit of air and water you let out lowers the pressure in a sealed system. Bleed two or three radiators and the gauge can drop enough for the boiler to complain or lock out.

Look at the gauge on the front of the boiler, or the pressure reading on the display. Baxi says it should be around 1.5 bar. Most manufacturers give a range of about 1 to 1.5 bar with the system cold, and your manual will have the exact figure for your model.

If it's low, top it up through the filling loop. Our boiler pressure guide shows how, and what to do if the pressure won't hold.

If you have tanks in the loft

Older heating systems with a regular boiler are often open-vented. A small tank in the loft, the feed and expansion tank, tops the heating water up on its own. There's no filling loop to use and no need to repressurise after bleeding. If you're not sure which you have, our pressure guide explains the difference.

Which radiator should you bleed first?

None of the manufacturers we checked set an order. Baxi and Worcester Bosch just say to bleed each radiator that needs it.

A common habit among heating engineers is to start downstairs and work up, because air rises and tends to collect in the top-floor radiators. It does no harm to do it that way, but it isn't a rule. What matters more is checking the pressure after you've finished.

When bleeding doesn't fix it

Bleeding only gets rid of air. If a radiator is still cold afterwards, it's something else. These are the usual suspects.

Sludge

Black sludge, mostly magnetite from the inside of steel radiators, settles at the bottom. That's why a sludged radiator is cold at the bottom and warm at the top. Baxi says that if there are still cold spots after bleeding, sludge and debris may be the cause, and that your installer can flush and clean the system and treat the water with an inhibitor. Worcester Bosch says the same: the system needs flushing by an installer. Our power flush guide covers the options.

Closed or stuck valves

Each radiator has two valves at the bottom. One is the control you turn, often a thermostatic radiator valve (TRV) with numbers on it. The other, the lockshield, usually sits under a plain plastic cap. If either is shut, the radiator won't heat.

A TRV pin can also stick after a summer off. Our TRV guide explains how they work.

An unbalanced system

If radiators near the boiler roast while the furthest ones stay lukewarm, the system may need balancing. That means setting the lockshield valves so water is shared out evenly. It's fiddly and takes a while, so many people leave it to a heating engineer.

A problem at the boiler

If every radiator is cold, the issue is probably the boiler, the pump or the controls, not the radiators. Check for a fault code and our boiler not working guide. If you've got hot water but no heating, that guide covers it too.

Why does my radiator keep needing bleeding?

The odd bleed now and then is normal, since Worcester Bosch says air builds up during ordinary running. Needing it every few weeks isn't. Ideal, writing about whistling boilers, makes the point that a good engineer will want to know how air is getting into the system, because it shouldn't.

There's a fault somewhere letting it in, and you can't usually see it. That's a job for an engineer to trace, not something more bleeding will cure.

If you're topping up the pressure every time, too, that points to water escaping somewhere. Check under radiators and along visible pipes for damp, and look at the small pipe outside that comes from the boiler's pressure-relief valve. Our boiler leaking water guide has more on that.

Is it safe to bleed a radiator myself?

Yes, on a cooled system with the heating off, it's one of the few heating jobs you can safely do yourself. You're only releasing air and a little water from the radiator. You're not touching the boiler or anything gas-related.

Leave the rest to an engineer. That includes taking the boiler casing off, draining the system, flushing it, or fixing a valve that won't seal. On a gas boiler, anything inside the appliance is for a Gas Safe registered engineer only, as the HSE explains.

Sources

  • Baxi, "How to bleed a radiator in 8 easy steps", checked 28 November 2026.
  • Worcester Bosch, "How to bleed your radiators" homeowner guide, checked 28 November 2026.
  • Vaillant UK, "Why is my boiler making noise?", gurgling section, checked 28 November 2026.
  • Ideal Heating, "Why is my boiler making a noise?", checked 28 November 2026.
  • HSE, gas safety in the home, checked 28 November 2026.

Still got a cold radiator after bleeding? Book a repair online and a Gas Safe registered engineer will track it down.