Boiler not working? A safe checklist before you book a repair
A boiler not working can come down to lost power, meter credit, heating settings, low pressure or a frozen condensate pipe. Before touching any controls, read the safety advice below. If there are no safety warnings, work through the external checks in order and follow your boiler's manual.
If it still won't fire up, book a boiler repair online with Padly's Gas Safe registered, insured engineers.
- If you smell or suspect gas, do not use switches, boiler controls or a gas hob; follow the emergency advice below.
- Look up any fault code or warning light in your boiler manual.
- If a circuit breaker trips again, leave it alone and ask a registered electrician.
- Check the heating programme, clock and room thermostat.
- Arrange an engineer if the external checks do not get the boiler working.
Gas smell, carbon monoxide or an unsafe boiler
If you smell gas or suspect a gas leak: National Gas says not to smoke or light matches. Don't turn electrical switches on or off, including the boiler's controls and switches. Open doors and windows. Turn off the gas at the meter control handle unless the meter is in the cellar. Go outside and call the National Gas Emergency Service on 0800 111 999.
If a carbon monoxide alarm sounds or you suspect carbon monoxide: Stop using all appliances; switch them off only if there's no smell or suspicion of a gas leak. Open doors and windows to ventilate, then leave immediately. Call 0800 111 999 from outside, seek immediate medical help and wait for emergency advice before returning, as National Gas advises. HSE confirms that carbon monoxide has no smell. Fresh air alone won't treat exposure.
Orange pilot flame, or another worry that the boiler is unsafe, with no smell or suspicion of gas: don't relight it. Turn the boiler off and leave it untouched until a Gas Safe registered engineer has checked it, as Citizens Advice and HSE advise. For an orange pilot flame, Citizens Advice also says to go outside and call 0800 111 999.
Work through these external checks in order
Only continue if there is no smell or suspicion of gas and no other warning that the boiler is unsafe. Keep the casing closed. These checks cover the display and user controls; leave internal faults to a Gas Safe registered engineer, as Ideal advises.
1. Read the fault code or warning light
Find your boiler's user guide and look up the message before changing anything. Follow the instructions for that model. If it points to a problem outside the user checks, note down the message and its meaning for the engineer.
2. Check the electricity supply
Start with the rest of the house. Are the lights and other appliances working? A power cut can stop the boiler too. Check electricity prepayment credit, then the boiler's power switch and the wall switch supplying it. Vaillant also includes the isolation switch next to the boiler in its checks.
For the consumer unit, Citizens Advice gives this sequence: find the labelled boiler circuit breaker and move it to on if it is off. Check the main switch too. If either trips back to off, do not move it again. Ask a registered electrician to investigate.
3. Check gas credit and supply
Check the gas prepayment meter has credit as well.
Only if there is no gas smell, suspected leak, orange flame or other unsafe warning, Ideal suggests trying a gas hob for a few seconds to check the supply. A flame that dies down can point to the gas being off. Contact your gas supplier if you suspect a wider supply problem. With no other gas appliance, check the boiler display instead.
4. Look at the clock and heating controls
Check that heating is enabled on the boiler or programmer. Check off or summer mode, the clock and the programmed heating times. After a power cut, check the programme again: Vaillant notes that an outage can change the time settings.
Turn the room thermostat above the current room temperature to request heat. A setting below the room temperature will not bring the heating on. The guide to boiler controls explains the programme and thermostat settings.
5. Read the pressure gauge
Look on the boiler front or near the pipes underneath for the gauge. Use the manual to find the dial or digital display and its recommended reading.
On a Worcester Bosch Greenstar i, the guidance gives around 1 bar with heating off, usually rising to 1.5 bar or more in operation. Ideal's F1 guidance gives a top-up range of 1 to 1.5 bar. Vaillant's low-pressure guide gives typically around 1.5 bar cold. These are different checks, so use your own boiler's instructions.
For topping up, Citizens Advice says the heating should be off and the boiler cool. Follow the manual and close the valves properly afterwards. Vaillant warns that filling devices work differently: use the instructions for yours. If the gauge does not rise as you add water, close the filling loop immediately and call a Gas Safe registered engineer.
If pressure changes over the next week, arrange an engineer to inspect it. Read the boiler pressure guide for more help with the gauge, or the leaking boiler guide if you can see water escaping.
6. Look for frozen condensate in cold weather
A frozen waste pipe is another possibility when the weather turns cold. Citizens Advice describes an outside plastic condensate pipe, with gurgling, dripping or a fault code as possible clues. A frozen blockage can shut the boiler down, as Ideal explains.
Only try thawing a pipe you can reach safely. Use a hot water bottle or a cloth soaked in hot water, without putting weight on the pipe. Never use boiling water. The frozen condensate pipe guide covers the checks; leave an inaccessible pipe alone and arrange help.
7. Check for a pilot on an older boiler
Citizens Advice describes a blue pilot flame sometimes visible through an older boiler's front panel. Modern condensing boilers do not have a pilot light, as Vaillant notes. Keep the casing closed.
Do not attempt relighting if there is any gas smell or suspicion of a leak, an orange flame or another unsafe warning. With none of those warnings, follow only your boiler's own user instructions for relighting.
8. Try one reset, following the manual
Do the checks above before considering a reset. For this guide, stop after one attempt, using your model's manual. Do not reset if gas is suspected or the boiler seems unsafe. If the fault returns, arrange an engineer.
On Baxi boilers with a dedicated reset button, press it until the red lockout light clears. For the thermostat-knob arrangement, turn fully anticlockwise, hold until the red light clears, then restore the chosen temperature. With its selector-switch arrangement, hold R for at least five seconds before releasing. Use only the method that matches your manual.
No heating but hot water works
Look at the radiator valves as well as the timer and thermostat. Ideal includes individually closed radiator valves in its checks, particularly after summer. Hot taps do not tell you whether the heating programme is enabled. Check for off or summer mode and a thermostat setting below the room's temperature.
No hot water
Check that hot water is enabled at the boiler or programmer. If you have a separate cylinder, check its programme and thermostat too. A cylinder that has run out needs time to heat again. For a combi, Citizens Advice suggests running the hot tap for a minute to see whether it warms up.
Use the no hot water guide for checks focused on cold taps.
Boiler won't fire up / ignite
An illuminated display does not tell you why the burner has stayed off. Check whether the thermostat is asking for heat and whether the programme is correct. Vaillant also lists electricity and gas supply problems, a faulty fan and a faulty gas valve among possible ignition causes. Leave internal parts to an engineer.
Notes for the make on your boiler
Worcester Bosch
On a Greenstar i, the information button gives text about the current boiler status. If no lights stay lit, check the electricity supply carefully or ask for help. If power is present but the lights remain out, Worcester Bosch directs you to an engineer.
Vaillant
Check the recommended pressure boundaries in your boiler manual. Vaillant says filling devices differ, so follow the instructions for your particular device. If the gauge fails to rise, close the filling loop and call a Gas Safe registered engineer.
Ideal
On Ideal's fault-code guide, F1 means low pressure, while L2 means flame loss or ignition lockout. Gurgling while trying to fire may indicate a blockage needing the installer. L5 means too many resets within 15 minutes. Note the code for the engineer instead of repeatedly trying again.
Baxi
E133 in Baxi's reset example can indicate a gas supply, ignition or flame problem, or blocked condensate. It does not identify one cause on its own. Frequent lockouts need an installer or service engineer to investigate.
When to stop and book an engineer
Stop at the external checks. Ideal and Worcester Bosch both direct you to an engineer if those checks have not restored operation. Leaks and suspected internal faults also need qualified help. Do not open the casing or try to repair ignition parts, pumps, internal electrics or the expansion vessel.
HSE says gas workers must be Gas Safe registered and competent for the particular work. Check the back of the engineer's ID card for those competencies.
If you rent in England, tell your landlord the boiler has stopped working. They are responsible for repair or replacement; do not attempt the repair yourself.
Check existing warranty, guarantee and insurance documents before arranging work. Compare parts and labour cover and any excess. Cover may also come through workplace benefits or a packaged bank account. If the paperwork is missing, ask the manufacturer whether the boiler is covered.
If the checks haven't brought it back, you can book a boiler repair through the online form. Every Padly engineer is Gas Safe registered and insured, Padly checks this, and Padly carries its own insurance up to £10m.
Checked on 27 November 2026. Sources: Citizens Advice broken-boiler checklist | Ideal troubleshooting and fault codes | Worcester Bosch broken-boiler and Greenstar i guidance | Vaillant ignition and low-pressure guidance | Baxi reset instructions | HSE domestic gas FAQs | HSE carbon monoxide guidance | National Gas emergency contacts.
Related Padly guides
- Checks when the hot taps run cold
- Reading and checking boiler pressure
- Thawing a frozen condensate pipe
- What to do about leaking boiler water
- Understanding heating programmes and thermostats
- Boiler servicing explained
Frequently asked questions
Why does my boiler have power but no heating?
A powered boiler may still have heating disabled, a timer outside its heating period or a thermostat set below room temperature. Check those settings first, provided there is no unsafe warning and no smell or suspicion of gas. For an Ideal boiler, low or high pressure can also cause shutdown.
Why does my boiler heat the taps but leave radiators cold?
Check whether the boiler heating programme is enabled and the room thermostat is above the current temperature. Ideal also recommends checking that the individual radiator valves have not been closed.
How do I choose the right boiler reset method?
Do not reset a boiler if you smell or suspect gas, see an orange flame or think it is unsafe. Otherwise, use the boiler model's manual. Baxi describes reset buttons, thermostat knobs and selector switches on different boilers; one method does not suit them all.
Should I keep resetting a boiler that locks out?
No. If gas is suspected, do not operate electrical switches or boiler controls. Leave any boiler you suspect is unsafe untouched. With no safety warning, try at most one reset following your boiler's manual. If the fault returns, arrange a Gas Safe registered engineer; Baxi refers frequent lockouts for investigation.
Can a warm room stop my boiler firing up?
Yes, the boiler may have no demand for heating. Vaillant explains that a room already warmer than the thermostat setting can account for a boiler not igniting. Check the requested temperature and the heating programme before assuming there is an ignition fault.
What pressure reading is right for my boiler?
Use your boiler manual. Worcester Bosch gives around 1 bar with heating off for the Greenstar i, usually rising to 1.5 bar or more during operation. Vaillant's low-pressure guidance gives typically around 1.5 bar cold.
What if filling does not raise my boiler pressure?
Vaillant says to close the filling loop immediately if adding water does not increase boiler pressure, then call a Gas Safe registered engineer. Leave further checks to the engineer rather than continuing to fill the system.
Who arranges a boiler repair if I rent?
For a rented home in England, report the failed boiler to your landlord. Citizens Advice says the landlord is responsible for the repair or replacement. Let the landlord arrange the work rather than attempting a boiler repair yourself.
Still need help? Book a boiler repair online.